8SVY
MBP-Mcl1 in complex with ligand 10
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-12-15 |
Detector | DECTRIS EIGER2 X 16M |
Wavelength(s) | 1.0000 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 99.040, 137.032, 38.715 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 37.280 - 1.470 |
R-factor | 0.17176 |
Rwork | 0.170 |
R-free | 0.20633 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 1.421 |
Data reduction software | autoPROC (1.1.7) |
Data scaling software | autoPROC ((Version 1.1.7)) |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 37.280 | 1.490 |
High resolution limit [Å] | 1.470 | 1.470 |
Rmeas | 0.054 | 1.360 |
Rpim | 0.021 | 0.527 |
Number of reflections | 89536 | 4501 |
<I/σ(I)> | 16.6 | 1.4 |
Completeness [%] | 98.4 | 99.5 |
Redundancy | 6.5 | |
CC(1/2) | 0.999 | 0.563 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 7.5 | 285 | 19% (w/v) PEG3350, 0.17M Mg formate |