8S8S
An induced-fit motion of a mobile loop
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-12-10 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 44.272, 58.059, 82.383 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.458 - 1.314 |
R-factor | 0.1889 |
Rwork | 0.188 |
R-free | 0.20950 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.760 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((1.14_3260: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.460 | 47.460 |
High resolution limit [Å] | 1.314 | 1.314 |
Number of reflections | 49373 | 49373 |
<I/σ(I)> | 12.86 | |
Completeness [%] | 96.2 | |
Redundancy | 12.3 | |
CC(1/2) | 0.999 | 0.999 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 277 | ammonium phosphate |