Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

8QYP

Beta-cardiac myosin motor domain in the pre-powerstroke state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2017-08-28
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.98007
Spacegroup nameP 43 2 2
Unit cell lengths94.397, 94.397, 219.693
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution94.400 - 2.759
R-factor0.1926
Rwork0.190
R-free0.24780
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.009
RMSD bond angle1.020
Data reduction softwareautoPROC
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.3 (18-SEP-2020))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]94.4003.033
High resolution limit [Å]2.7592.759
Rmerge0.2732.413
Number of reflections201661009
<I/σ(I)>10.81.5
Completeness [%]94.464.2
Redundancy25.9
CC(1/2)0.9990.710
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.52900.5M Lithium Sulfate 0.1M Tris-HCl 25% PEG 3350 2mM Mg.ADP.Vanadate

245663

PDB entries from 2025-12-03

PDB statisticsPDBj update infoContact PDBjnumon