Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8OSM

GTPASE HRAS IN COMPLEX WITH ZN-CYCLEN AT 200 MPA PRESSURE

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE CRISTAL
Synchrotron siteSOLEIL
BeamlineCRISTAL
Temperature [K]293
Detector technologyCCD
Collection date2015-07-22
DetectorRAYONIX SX-165mm
Wavelength(s)0.51035
Spacegroup nameP 32 2 1
Unit cell lengths39.371, 39.371, 158.899
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution33.340 - 2.050
R-factor0.1738
Rwork0.171
R-free0.22410
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.002
RMSD bond angle0.485
Data reduction softwareXDS
Data scaling softwareSCALA (3.3.22)
Phasing softwarePHASER (2.8.3)
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.7202.160
High resolution limit [Å]2.0502.050
Rmerge0.1000.735
Rmeas0.1100.807
Rpim0.0440.320
Total number of observations428096112
Number of reflections83801192
<I/σ(I)>11.22.7
Completeness [%]87.3
Redundancy5.15.1
CC(1/2)0.9980.793
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1BATCH MODE7.529340 MM TRIS HCL, 10 MM MGCL2, 2 MM DTE, 26-30 % PEG-400

225946

PDB entries from 2024-10-09

PDB statisticsPDBj update infoContact PDBjnumon