8OIC

Trichomonas vaginalis riboside hydrolase (His-tagged)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2020-01-23
DetectorDECTRIS EIGER2 X 16M
Wavelength(s)0.9795
Spacegroup nameP 1
Unit cell lengths73.055, 94.665, 120.589
Unit cell angles105.08, 89.96, 93.83
Refinement procedure
Resolution116.418 - 2.800
Rwork0.209
R-free0.25080
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.006
RMSD bond angle1.205
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0405)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]116.4202.623
High resolution limit [Å]2.5782.578
Rpim0.0890.855
Number of reflections966994868
<I/σ(I)>6.30.9
Completeness [%]98.598.2
Redundancy3.73.8
CC(1/2)0.9930.361
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5291.150.1 M bicine pH 8.5, 20% (w/v) PEG 5000 monomethyl ether, 3% sucrose

219869

PDB entries from 2024-05-15