8JGD
GDP-bound KRAS G12C in complex with YK-8S
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CAMD BEAMLINE GCPCC |
Synchrotron site | CAMD |
Beamline | GCPCC |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-04-01 |
Detector | DECTRIS PILATUS 300K |
Wavelength(s) | 0.987 |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 82.284, 82.284, 97.479 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 41.142 - 1.600 |
R-factor | 0.170771429201 |
Rwork | 0.168 |
R-free | 0.20147 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.213 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692+SVN) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 41.142 | 1.630 |
High resolution limit [Å] | 1.600 | 1.600 |
Number of reflections | 26269 | 26269 |
<I/σ(I)> | 40.4 | |
Completeness [%] | 100.0 | |
Redundancy | 28.6 | |
CC(1/2) | 0.968 | 0.980 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 277 | 200mM calcium acetate,100mM MES(PH 5.5-6.5),PEG 8000 16%-24% |