Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8J5I

MALT1 death domain

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSRRC BEAMLINE BL15A1
Synchrotron siteNSRRC
BeamlineBL15A1
Temperature [K]103
Detector technologyCCD
Collection date2019-12-10
DetectorADSC QUANTUM 315r
Wavelength(s)1.0
Spacegroup nameI 2 2 2
Unit cell lengths35.232, 83.229, 85.403
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution21.350 - 2.100
R-factor0.2191
Rwork0.218
R-free0.24070
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.005
RMSD bond angle0.867
Data reduction softwareHKL-2000 (HKL-2000)
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.19.2_4158: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0002.160
High resolution limit [Å]2.1002.100
Rmerge0.0460.487
Rmeas0.0540.568
Rpim0.0280.289
Number of reflections7761728
<I/σ(I)>14.82.98
Completeness [%]99.2
Redundancy3.6
CC(1/2)0.9901.000
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION291PEG 3350, Tacsimate pH 6

220113

PDB entries from 2024-05-22