8HY9

Bacterial STING from Riemerella anatipestifer in complex with 3'3'-c-di-GMP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSRRC BEAMLINE TPS 07A
Synchrotron siteNSRRC
BeamlineTPS 07A
Temperature [K]100
Detector technologyPIXEL
Collection date2022-10-13
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.97624
Spacegroup nameC 1 2 1
Unit cell lengths99.510, 40.990, 36.196
Unit cell angles90.00, 105.04, 90.00
Refinement procedure
Resolution22.805 - 1.462
Rwork0.181
R-free0.20950
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7ebd
RMSD bond length0.012
RMSD bond angle1.437
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0001.510
High resolution limit [Å]1.4601.460
Rmerge0.0540.489
Number of reflections242482302
<I/σ(I)>30.2272.92
Completeness [%]99.395
Redundancy6.24.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2770.1 M Tris pH 8.5, 0.2 M calcium chloride dihydrate, 40 % v/v PEG 4000

219869

PDB entries from 2024-05-15