8EN8
Cross-reactive 3180 TCR recognition of HLA-B*35:01-NP4 epitope from 1972 influenza strain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2019-03-21 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.95370 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 79.770, 116.686, 253.184 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 27.196 - 2.700 |
R-factor | 0.209126284475 |
Rwork | 0.207 |
R-free | 0.24852 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3lks |
RMSD bond length | 0.012 |
RMSD bond angle | 1.623 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | BUSTER |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 27.200 | 2.800 |
High resolution limit [Å] | 2.700 | 2.700 |
Rmerge | 0.586 | |
Rmeas | 0.072 | |
Number of reflections | 65736 | 6466 |
<I/σ(I)> | 13.9 | 2 |
Completeness [%] | 100.0 | |
Redundancy | 2 | |
CC(1/2) | 0.993 | 0.702 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 297 | PEG |