8E7W
RsTSPO A139T with Heme
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-B |
Synchrotron site | APS |
Beamline | 23-ID-B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-07-28 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.033 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 58.399, 99.568, 95.812 |
Unit cell angles | 90.00, 100.16, 90.00 |
Refinement procedure
Resolution | 28.950 - 2.100 |
R-factor | 0.1968 |
Rwork | 0.195 |
R-free | 0.25250 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4uc1 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 28.950 | 2.180 |
High resolution limit [Å] | 2.100 | 2.100 |
Rmerge | 0.078 | 0.482 |
Number of reflections | 31427 | 3098 |
<I/σ(I)> | 6 | 2 |
Completeness [%] | 99.8 | 99 |
Redundancy | 2 | |
CC(1/2) | 0.992 | 0.583 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | LIPIDIC CUBIC PHASE | 293 | 28-30% PEG400, HEPES (pH 8.5), 100mM sodium acetate, 100 mM ammonium acetate |