Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8E7W

RsTSPO A139T with Heme

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-B
Synchrotron siteAPS
Beamline23-ID-B
Temperature [K]100
Detector technologyPIXEL
Collection date2017-07-28
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.033
Spacegroup nameC 1 2 1
Unit cell lengths58.399, 99.568, 95.812
Unit cell angles90.00, 100.16, 90.00
Refinement procedure
Resolution28.950 - 2.100
R-factor0.1968
Rwork0.195
R-free0.25250
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4uc1
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]28.9502.180
High resolution limit [Å]2.1002.100
Rmerge0.0780.482
Number of reflections314273098
<I/σ(I)>62
Completeness [%]99.899
Redundancy2
CC(1/2)0.9920.583
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1LIPIDIC CUBIC PHASE29328-30% PEG400, HEPES (pH 8.5), 100mM sodium acetate, 100 mM ammonium acetate

219869

PDB entries from 2024-05-15