Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8DYI

IL17A homodimer bound to Compound 5

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2016-02-17
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.00
Spacegroup nameC 1 2 1
Unit cell lengths172.938, 30.507, 50.239
Unit cell angles90.00, 102.71, 90.00
Refinement procedure
Resolution38.830 - 2.280
R-factor0.274
Rwork0.272
R-free0.31140
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4hr9
RMSD bond length0.008
RMSD bond angle1.158
Data reduction softwareautoPROC
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]42.1702.272
High resolution limit [Å]2.2602.264
Number of reflections12501102
<I/σ(I)>8.4
Completeness [%]97.9
Redundancy3.2
CC(1/2)0.9900.802
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION290.153.2M NaCl, 0.1M Tris, pH 8.5

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon