8DYH

IL17A homodimer bound to Compound 6

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2016-02-10
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.0
Spacegroup nameC 1 2 1
Unit cell lengths170.516, 35.710, 45.715
Unit cell angles90.00, 97.79, 90.00
Refinement procedure
Resolution37.840 - 1.940
R-factor0.2134
Rwork0.212
R-free0.24760
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4hr9
RMSD bond length0.008
RMSD bond angle1.082
Data reduction softwareautoPROC
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.3001.942
High resolution limit [Å]1.9001.935
Number of reflections19678148
<I/σ(I)>6.8
Completeness [%]82.2
Redundancy3.1
CC(1/2)0.9900.620
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION290.153.2M NaCl, 0.1M Tris, pH 8.5

219869