8D5Q
TCR TG6 in complex with Ld-HF10
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-02-02 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9792 |
Spacegroup name | P 41 |
Unit cell lengths | 89.963, 89.963, 105.982 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 90.000 | 2.540 |
High resolution limit [Å] | 2.500 | 2.500 |
Rpim | 0.030 | 0.290 |
Number of reflections | 29168 | 2864 |
<I/σ(I)> | 26.6 | |
Completeness [%] | 99.8 | |
Redundancy | 6.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 277 | 11 % w/v PEG 8000, 0.1 M MES 6.0, 0.24 M Ammonium sulfate |