8CQH
Ntaya virus methyltransferase in complex with GTP and SAH
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-02-23 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 1.541870 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 38.250, 71.655, 50.413 |
Unit cell angles | 90.00, 93.15, 90.00 |
Refinement procedure
Resolution | 27.400 - 2.000 |
R-factor | 0.154 |
Rwork | 0.152 |
R-free | 0.18980 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 0.873 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 27.400 | 2.070 |
High resolution limit [Å] | 2.000 | 2.000 |
Number of reflections | 18427 | 1817 |
<I/σ(I)> | 22.1 | 7.2 |
Completeness [%] | 99.9 | |
Redundancy | 13.3 | |
CC(1/2) | 0.998 | 0.964 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291 | 0.1M Trizma/Bicine pH 8.5, 0.02M monosacharides, 10% (w/v) PEG4000, 20% glycerol |