8CK5

VDR LBD complex with 25-nitro derivative of 1,25D3

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2014-07-03
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.979
Spacegroup nameP 65 2 2
Unit cell lengths65.701, 65.701, 262.106
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution47.680 - 2.100
R-factor0.1932
Rwork0.191
R-free0.24280
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.008
RMSD bond angle1.060
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.6802.175
High resolution limit [Å]2.1002.100
Number of reflections20625580
<I/σ(I)>12.91
Completeness [%]81.9
Redundancy12.6
CC(1/2)0.9970.895
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.529350 mM Bis-Tris pH 6.5, 1.6 M lithium sulfate and 50 mM magnesium sulfate