IPNS H270A variant in complex with ACV exposed to O2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2022-09-13
DetectorDECTRIS EIGER2 XE 16M
Wavelength(s)0.9763
Spacegroup nameP 21 21 21
Unit cell lengths41.300, 74.250, 101.010
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution41.760 - 1.570
R-factor0.1798
Rwork0.178
R-free0.20530
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6zae
Data reduction softwareDIALS
Data scaling softwareAimless (0.7.9)
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]41.76041.7601.610
High resolution limit [Å]1.5707.0201.570
Rmerge0.2170.0473.415
Rmeas0.2260.0493.564
Rpim0.0620.0141.008
Total number of observations588792
Number of reflections442495883213
<I/σ(I)>80.7
Completeness [%]100.099.899.6
Redundancy13.311.912.2
CC(1/2)0.9980.9990.512
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1BATCH MODE8.32981.7 M Li2SO4, 0.1 M Tris pH 8.3

227344

PDB entries from 2024-11-13