Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8AZR

KRAS in complex with precursor 1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSEALED TUBE
Source detailsBRUKER IMUS 3.0 MICROFOCUS
Temperature [K]100
Detector technologyCMOS
Collection date2022-09-02
DetectorBRUKER PHOTON 100
Wavelength(s)1.54000
Spacegroup nameP 21 21 2
Unit cell lengths86.847, 40.300, 55.887
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.000 - 1.600
R-factor0.182
Rwork0.179
R-free0.23240
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)8afb
RMSD bond length0.008
RMSD bond angle0.976
Data reduction softwareXDS
Data scaling softwareSTARANISO
Phasing softwarePHASER
Refinement softwarePHENIX (1.20_4459)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.1001.122
High resolution limit [Å]1.0471.047
Number of reflections776123882
<I/σ(I)>201.6
Completeness [%]82.622.2
Redundancy4.77.5
CC(1/2)1.0000.700
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2770.2mM Magnesiumchloride, 20% PEG 2000, 100mM sodium acetate pH 4.4

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon