8AQD
Hydrophobic probe bound to Streptavidin - 1
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-07-02 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.0000413700316724 |
Spacegroup name | I 41 2 2 |
Unit cell lengths | 57.581, 57.581, 183.943 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 46.030 - 1.450 |
R-factor | 0.187 |
Rwork | 0.184 |
R-free | 0.23960 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3pk2 |
RMSD bond length | 0.009 |
RMSD bond angle | 1.502 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0352) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.030 | 1.470 |
High resolution limit [Å] | 1.450 | 1.450 |
Number of reflections | 28050 | 1360 |
<I/σ(I)> | 15.4 | |
Completeness [%] | 100.0 | |
Redundancy | 20 | |
CC(1/2) | 0.997 | 0.812 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4 | 293 | 25 w/v% PEG 3350 0.1 M sodium acetate pH 4.0 |