Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, DESY BEAMLINE P11
Synchrotron sitePETRA III, DESY
BeamlineP11
Temperature [K]100
Detector technologyPIXEL
Collection date2022-05-28
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0332
Spacegroup nameP 1 21 1
Unit cell lengths45.253, 54.376, 114.192
Unit cell angles90.00, 101.38, 90.00
Refinement procedure
Resolution48.959 - 2.519
Rwork0.186
R-free0.26610
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6y2e
RMSD bond length0.008
RMSD bond angle1.671
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.9592.610
High resolution limit [Å]2.5192.520
Number of reflections183911790
<I/σ(I)>6.4
Completeness [%]98.6
Redundancy4.9
CC(1/2)0.9880.599
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP62930.1MMES pH 6, 0.2MSodium chloride, 20% w/vPEG 6000, 10% v/vEthylene glycol

219869