Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8ADC

Viral tegument-like DUBs

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, EMBL c/o DESY BEAMLINE P13 (MX1)
Synchrotron sitePETRA III, EMBL c/o DESY
BeamlineP13 (MX1)
Temperature [K]100
Detector technologyPIXEL
Collection date2021-08-24
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9762
Spacegroup nameP 1 21 1
Unit cell lengths37.121, 70.295, 75.890
Unit cell angles90.00, 101.84, 90.00
Refinement procedure
Resolution51.060 - 1.700
R-factor0.1993
Rwork0.198
R-free0.23510
Structure solution methodSIR
RMSD bond length0.007
RMSD bond angle0.836
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareSHELXDE
Refinement softwarePHENIX (1.20_4478)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]80.0001.800
High resolution limit [Å]1.7001.700
Rmerge0.0791.180
Rmeas0.0801.410
Number of reflections8165913147
<I/σ(I)>8.51
Completeness [%]98.898.3
Redundancy3.43.1
CC(1/2)0.9970.535
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.52980.2 M sodium chloride, 0.1 M BisTris pH 5.5, 25 % w/v PEG 3350

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon