Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7ZY1

I567A Mutant of Recombinant CODH-II

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-03-14
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.91841
Spacegroup nameC 1 2 1
Unit cell lengths111.669, 75.809, 71.500
Unit cell angles90.00, 111.11, 90.00
Refinement procedure
Resolution34.240 - 1.434
R-factor0.1294
Rwork0.129
R-free0.14410
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3b51
RMSD bond length0.009
RMSD bond angle1.476
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHENIX
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]41.0101.490
High resolution limit [Å]1.4301.430
Rmerge0.0580.541
Rmeas0.0680.633
Number of reflections1009979818
<I/σ(I)>11.71.9
Completeness [%]99.4
Redundancy3.69
CC(1/2)0.9980.707
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5291.150.1M Bis-Tris pH 6.5, PEG 3350 10-18%, Ammonium sulphate 0.18M

222926

PDB entries from 2024-07-24