Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7ZLW

NME1 in complex with ADP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE MASSIF-1
Synchrotron siteESRF
BeamlineMASSIF-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-20
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.966000
Spacegroup nameP 1 21 1
Unit cell lengths51.656, 70.193, 113.167
Unit cell angles90.00, 90.96, 90.00
Refinement procedure
Resolution59.650 - 2.200
R-factor0.1738
Rwork0.171
R-free0.22010
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2hvd
Data reduction softwareXDS (Jan 26, 2018)
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]59.6502.270
High resolution limit [Å]2.2002.200
Rmerge0.0280.309
Rmeas0.0390.437
Rpim0.0280.309
Number of reflections405173536
<I/σ(I)>11.41.7
Completeness [%]98.298.9
Redundancy2.52.5
CC(1/2)0.9990.877
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8293.15PEG 400, NaCl, Tris

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon