7ZCV
Rgg144 of Streptococcus pneumoniae
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-08-09 |
Detector | DECTRIS EIGER X 4M |
Wavelength(s) | 0.9795 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 75.479, 80.871, 106.534 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 32.510 - 1.900 |
R-factor | 0.1898 |
Rwork | 0.189 |
R-free | 0.21490 |
Structure solution method | SAD |
Data reduction software | XDS |
Data scaling software | xia2 |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 32.510 | 1.940 |
High resolution limit [Å] | 1.900 | 1.900 |
Rmerge | 1.031 | |
Rpim | 0.412 | |
Number of reflections | 52047 | 5148 |
<I/σ(I)> | 12.3 | 2 |
Completeness [%] | 99.9 | |
Redundancy | 6 | |
CC(1/2) | 0.998 | 0.526 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 100 mM Bis-Tris propane pH 7.5, containing 200 mM potassium sodium tartrate tetrahydrate and PEG4K (18-26%) |