Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-07-28 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9762 |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 79.297, 79.297, 138.390 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 61.520 - 1.470 |
Rwork | 0.201 |
R-free | 0.21760 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3dai |
RMSD bond length | 0.025 |
RMSD bond angle | 2.393 |
Data reduction software | xia2 |
Data scaling software | Aimless (0.7.4) |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 61.520 | 61.520 | 1.500 |
High resolution limit [Å] | 1.470 | 8.050 | 1.470 |
Rmerge | 0.088 | 0.046 | 4.861 |
Rmeas | 0.093 | 0.049 | 5.255 |
Rpim | 0.027 | 0.015 | 1.903 |
Number of reflections | 44189 | 341 | 2048 |
<I/σ(I)> | 16.8 | ||
Completeness [%] | 99.4 | ||
Redundancy | 20.5 | 15.5 | 13.4 |
CC(1/2) | 0.999 | 0.999 | 0.254 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | 0.1M BisTris pH 6-7, 1.7-2.1M Ammonium sulphate |