7XEK
SufS with D-cysteine for 30 min
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE BL-5A |
| Synchrotron site | Photon Factory |
| Beamline | BL-5A |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-10-26 |
| Detector | DECTRIS PILATUS3 S 6M |
| Wavelength(s) | 1.000 |
| Spacegroup name | P 31 2 1 |
| Unit cell lengths | 92.800, 92.800, 128.900 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 46.400 - 1.880 |
| R-factor | 0.1504 |
| Rwork | 0.149 |
| R-free | 0.17940 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 5zs9 |
| RMSD bond length | 0.021 |
| RMSD bond angle | 2.450 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | MOLREP |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 46.400 | 46.400 | 1.980 |
| High resolution limit [Å] | 1.880 | 10.000 | 1.880 |
| Rmerge | 0.052 | 0.013 | 0.663 |
| Rmeas | 0.056 | 0.014 | 0.717 |
| Total number of observations | 345688 | ||
| Number of reflections | 52726 | 406 | 7544 |
| <I/σ(I)> | 21.75 | 69.5 | 2.72 |
| Completeness [%] | 99.8 | 97.1 | 100 |
| Redundancy | 6.556 | 6.123 | 6.777 |
| CC(1/2) | 1.000 | 1.000 | 0.824 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 0.1 M Tris-HCl, 50 mM Lithium sulfate, 50% (v/v) PEG200 |