7XDP
Tunnel-redesigned O2-tolerant CO dehydrogenase for removal of CO in real flue gas (ChCODH2 A559S mutant in anaerobic condition)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 5C (4A) |
| Synchrotron site | PAL/PLS |
| Beamline | 5C (4A) |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-02-21 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1.000 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 111.934, 74.969, 71.323 |
| Unit cell angles | 90.00, 111.29, 90.00 |
Refinement procedure
| Resolution | 33.230 - 1.840 |
| R-factor | 0.1506 |
| Rwork | 0.148 |
| R-free | 0.19300 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1su7 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 1.870 |
| High resolution limit [Å] | 1.840 | 4.990 | 1.840 |
| Rmerge | 0.103 | 0.060 | 0.538 |
| Rmeas | 0.112 | 0.065 | 0.581 |
| Rpim | 0.043 | 0.024 | 0.219 |
| Total number of observations | 325933 | ||
| Number of reflections | 47693 | 2461 | 2391 |
| <I/σ(I)> | 5.4 | ||
| Completeness [%] | 99.9 | 99.7 | 100 |
| Redundancy | 6.8 | 7.4 | 7 |
| CC(1/2) | 0.997 | 0.896 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 295.15 | 0.1 M HEPES/NaOH pH 7.5, 200 mM MgCl2, 25% (w/v) polyethylene glycol 3350 |