7XDN
Tunnel-redesigned O2-tolerant CO dehydrogenase for removal of CO in real flue gas (ChCODH2 A559H mutant in anaerobic condition)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 5C (4A) |
| Synchrotron site | PAL/PLS |
| Beamline | 5C (4A) |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-02-21 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1.000 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 111.859, 76.026, 71.613 |
| Unit cell angles | 90.00, 111.59, 90.00 |
Refinement procedure
| Resolution | 35.190 - 1.800 |
| R-factor | 0.1661 |
| Rwork | 0.164 |
| R-free | 0.19970 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1su7 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 1.830 |
| High resolution limit [Å] | 1.800 | 4.880 | 1.800 |
| Rmerge | 0.091 | 0.048 | 0.647 |
| Rmeas | 0.099 | 0.052 | 0.700 |
| Rpim | 0.038 | 0.019 | 0.267 |
| Total number of observations | 352221 | ||
| Number of reflections | 51563 | 2639 | 2611 |
| <I/σ(I)> | 5.7 | ||
| Completeness [%] | 99.9 | 99.4 | 100 |
| Redundancy | 6.8 | 7.2 | 6.6 |
| CC(1/2) | 0.997 | 0.862 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 295.15 | 0.1 M HEPES/NaOH pH 7.5, 200 mM MgCl2, 25% (w/v) polyethylene glycol 3350 |