7X2P

Legionella pneumophila effector RavL

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U
Synchrotron siteSSRF
BeamlineBL17U
Temperature [K]100
Detector technologyCCD
Collection date2018-02-06
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.987
Spacegroup nameP 1 21 1
Unit cell lengths37.377, 54.247, 128.209
Unit cell angles90.00, 93.61, 90.00
Refinement procedure
Resolution33.150 - 2.890
R-factor0.2893
Rwork0.284
R-free0.33680
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7a16
RMSD bond length0.006
RMSD bond angle1.062
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.18.2_3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]33.15010.000
High resolution limit [Å]2.8902.890
Number of reflections99749974
<I/σ(I)>0.1
Completeness [%]85.0
Redundancy10
CC(1/2)0.8400.740
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52910.1M HEPES sodium pH 7.5, 0.8M potassium tartate

223166