7WDQ
DsyB in complex with SAM
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL18U1 |
| Synchrotron site | SSRF |
| Beamline | BL18U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2015-12-05 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 76.490, 115.931, 153.097 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 31.940 - 2.350 |
| R-factor | 0.1955 |
| Rwork | 0.192 |
| R-free | 0.25330 |
| Structure solution method | SAD |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.156 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.6.4_486) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 2.490 |
| High resolution limit [Å] | 2.350 | 5.171 | 2.400 |
| Rmerge | 0.086 | 0.046 | 0.495 |
| Rmeas | 0.093 | 0.050 | 0.535 |
| Rpim | 0.035 | 0.019 | 0.201 |
| Number of reflections | 56091 | 5892 | 5536 |
| <I/σ(I)> | 15.6 | ||
| Completeness [%] | 99.9 | 99.3 | 100 |
| Redundancy | 6.8 | 6.8 | 7 |
| CC(1/2) | 0.998 | 0.919 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.2 M NaCl, 0.1 M Hepes (pH 7.5) and 25% (wt/vol) polyethylene glycol (PEG) 3350 |