7VSY

Pim1 with N82K mutation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSRRC BEAMLINE BL13B1
Synchrotron siteNSRRC
BeamlineBL13B1
Temperature [K]80
Detector technologyCCD
Collection date2020-03-13
DetectorADSC QUANTUM 315r
Wavelength(s)1
Spacegroup nameP 65
Unit cell lengths97.673, 97.673, 80.499
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution25.034 - 2.141
R-factor0.1983
Rwork0.196
R-free0.22020
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.011
RMSD bond angle1.158
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]30.00030.0002.220
High resolution limit [Å]2.1404.6102.140
Rmerge0.0620.0351.067
Rmeas0.0650.0371.125
Rpim0.0200.0110.356
Total number of observations265143
Number of reflections2411924672403
<I/σ(I)>14
Completeness [%]100.099.6100
Redundancy1110.69.9
CC(1/2)0.9990.861
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7.5277Na.HEPES, NaCl