7UVS

Pfs230 domain 1 bound by LMIV230-02 Fab

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-B
Synchrotron siteAPS
Beamline23-ID-B
Temperature [K]100
Detector technologyPIXEL
Collection date2021-09-24
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.033167
Spacegroup nameC 1 2 1
Unit cell lengths92.360, 132.470, 125.070
Unit cell angles90.00, 102.35, 90.00
Refinement procedure
Resolution29.850 - 2.060
R-factor0.1752
Rwork0.174
R-free0.21480
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6ohg
RMSD bond length0.008
RMSD bond angle1.042
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]29.8502.060
High resolution limit [Å]2.0302.030
Rmerge0.1291.224
Rmeas0.1391.343
Rpim0.0520.542
Number of reflections932784062
<I/σ(I)>9.51.5
Completeness [%]98.6
Redundancy7
CC(1/2)0.9970.562
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2980.3 M di-ammonium hydrogen citrate, 15 %(w/v) polyethylene glycol 3350