Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-06-16 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.97910 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 49.308, 41.661, 56.908 |
Unit cell angles | 90.00, 114.20, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 51.909 | 2.030 |
High resolution limit [Å] | 1.976 | 2.000 |
Number of reflections | 14817 | 701 |
<I/σ(I)> | 13.4 | 4.8 |
Completeness [%] | 97.0 | |
Redundancy | 4.2 | |
CC(1/2) | 0.991 | 0.907 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.2 M Magnesium Chloride 20% PEG 3350 |