7UBL
Transcription antitermination factor Qlambda in complex with Q-lambda-binding-element DNA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-02-14 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.987 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 131.102, 131.102, 49.545 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 46.352 - 2.177 |
R-factor | 0.1914 |
Rwork | 0.188 |
R-free | 0.22850 |
Structure solution method | SAD |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | AutoSol |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.352 | 2.220 |
High resolution limit [Å] | 2.177 | 2.177 |
Rmerge | 0.056 | 0.826 |
Number of reflections | 23174 | 1143 |
<I/σ(I)> | 26.7 | |
Completeness [%] | 99.5 | |
Redundancy | 6.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 292 | 0.1 M HEPES, pH 7, 1 M sodium citrate |