7U60
Integrin alpha IIB beta3 complex with cRGDfV
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-B |
Synchrotron site | APS |
Beamline | 23-ID-B |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-07-03 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 0.97948 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 260.890, 145.770, 105.160 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.600 - 2.550 |
R-factor | 0.1887 |
Rwork | 0.188 |
R-free | 0.22540 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3nig |
RMSD bond length | 0.003 |
RMSD bond angle | 0.594 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.620 |
High resolution limit [Å] | 2.550 | 2.550 |
Rmerge | 0.110 | 0.900 |
Number of reflections | 129549 | 18165 |
<I/σ(I)> | 11.4 | |
Completeness [%] | 98.8 | 98.5 |
Redundancy | 5.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 297 | 11-13% PEG 8000, 0.2 M Ammonium Sulfate, 0.1 M Tris-HCl, pH 8.9 |