7TEK
SARS-CoV-2 3CLPro in complex with N-(4-(1H-pyrazol-4-yl)phenyl)-N-(3-chlorobenzyl)-2-(pyridin-3-yl)acetamide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-F |
Synchrotron site | APS |
Beamline | 21-ID-F |
Temperature [K] | 80 |
Detector technology | CCD |
Collection date | 2021-10-17 |
Detector | RAYONIX MX-300 |
Wavelength(s) | 0.978 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 114.843, 53.561, 44.958 |
Unit cell angles | 90.00, 101.79, 90.00 |
Refinement procedure
Resolution | 34.100 - 2.200 |
R-factor | 0.2112 |
Rwork | 0.208 |
R-free | 0.27380 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6wqf |
RMSD bond length | 0.008 |
RMSD bond angle | 0.989 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.14-3260-000) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 34.100 | 2.300 |
High resolution limit [Å] | 2.200 | 2.200 |
Number of reflections | 13797 | 1371 |
<I/σ(I)> | 26.62 | |
Completeness [%] | 99.4 | |
Redundancy | 3.7 | |
CC(1/2) | 0.990 | 0.640 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 289.15 | 0.2 M Lithium sulfate monohydrate, 0.1 M Tris pH 8.5, 25% w/v Polyethylene glycol 3350 |