7SKG
Myocilin OLF mutant V329M
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2021-07-28 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 49.479, 50.730, 50.508 |
Unit cell angles | 90.00, 96.22, 90.00 |
Refinement procedure
Resolution | 35.690 - 1.330 |
R-factor | 0.1673 |
Rwork | 0.167 |
R-free | 0.18330 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6pke |
RMSD bond length | 0.005 |
RMSD bond angle | 0.879 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX (1.17.1_3660) |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 35.690 | 1.378 |
High resolution limit [Å] | 1.330 | 1.330 |
Rmerge | 0.087 | 0.501 |
Rmeas | 0.095 | 0.554 |
Rpim | 0.039 | 0.234 |
Number of reflections | 56446 | 5575 |
<I/σ(I)> | 23.02 | 5.58 |
Completeness [%] | 98.7 | 98.03 |
Redundancy | 5.8 | 5.4 |
CC(1/2) | 0.998 | 0.892 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.2 | 289 | 10% PEG 8000, 0.05M magnesium chloride |