Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7SKE

Myocilin OLF mutant R296H

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.2
Synchrotron siteALS
Beamline5.0.2
Temperature [K]80
Detector technologyPIXEL
Collection date2021-06-02
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths49.243, 50.721, 50.364
Unit cell angles90.00, 97.67, 90.00
Refinement procedure
Resolution35.580 - 1.240
R-factor0.174
Rwork0.173
R-free0.19250
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6pke
RMSD bond length0.004
RMSD bond angle0.860
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX (1.17.1_3660)
Refinement softwarePHENIX (1.17.1_3660)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.5801.284
High resolution limit [Å]1.2401.240
Rmerge0.0730.479
Rmeas0.0800.546
Rpim0.0330.255
Number of reflections679935562
<I/σ(I)>12.591.78
Completeness [%]97.580.39
Redundancy5.73.9
CC(1/2)0.9980.836
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.22898% PEG 8000, 0.05M magnesium chloride

225946

PDB entries from 2024-10-09

PDB statisticsPDBj update infoContact PDBjnumon