7SJU
Myocilin OLF mutant T293K
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2021-04-04 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 49.376, 50.602, 50.432 |
Unit cell angles | 90.00, 96.75, 90.00 |
Refinement procedure
Resolution | 35.600 - 1.391 |
R-factor | 0.1614 |
Rwork | 0.161 |
R-free | 0.17950 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6pke |
RMSD bond length | 0.005 |
RMSD bond angle | 0.877 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX (1.17.1_3660) |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 35.600 | 1.440 |
High resolution limit [Å] | 1.391 | 1.391 |
Rmerge | 0.068 | 0.186 |
Rmeas | 0.074 | 0.202 |
Rpim | 0.029 | 0.077 |
Number of reflections | 48219 | 4536 |
<I/σ(I)> | 26.38 | 10.21 |
Completeness [%] | 97.0 | 92.08 |
Redundancy | 6.5 | 6.7 |
CC(1/2) | 0.997 | 0.981 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 289 | 8% PEG 8000, 0.1M magnesium chloride |