7SEY
M. tb EgtD in complex with SGH
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-D |
Synchrotron site | APS |
Beamline | 21-ID-D |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2020-07-31 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.98 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 69.281, 69.281, 142.127 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 46.310 - 2.390 |
R-factor | 0.2259 |
Rwork | 0.220 |
R-free | 0.28210 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4uy5 |
Data reduction software | HKL-2000 |
Data scaling software | SCALA |
Phasing software | PHENIX |
Refinement software | PHENIX (1.19.1_4122) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.310 | 2.476 |
High resolution limit [Å] | 2.390 | 2.390 |
Rmerge | 1.925 | |
Number of reflections | 12689 | 759 |
<I/σ(I)> | 10 | |
Completeness [%] | 88.1 | |
Redundancy | 16.9 | |
CC(1/2) | 0.990 | 0.634 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298.15 | 0.2 M succinic acid pH 7.0 and 20 % w/v polyethylene glycol 1,000 |