Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7SB8

d(GA(CGA)5) parallel-stranded homo-duplex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2020-11-12
DetectorDECTRIS EIGER2 X 16M
Wavelength(s)0.979
Spacegroup nameP 1 21 1
Unit cell lengths19.677, 30.422, 180.822
Unit cell angles90.00, 90.41, 90.00
Refinement procedure
Resolution90.409 - 1.317
R-factor0.1734
Rwork0.171
R-free0.21390
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ixj
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]90.4101.340
High resolution limit [Å]1.3171.317
Rmerge0.0930.669
Rmeas0.1060.757
Rpim0.0490.350
Number of reflections482322175
<I/σ(I)>9.92
Completeness [%]94.7
Redundancy4.5
CC(1/2)0.9950.820
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.42958% PEG400, 96 mM strontium chloride, 32 mM lithium chloride, 8 mM hexamminecobalt(III) chloride, 24 mM sodium cacodylate, equilibrated against 30% PEG400

221371

PDB entries from 2024-06-19

PDB statisticsPDBj update infoContact PDBjnumon