7S8I
PHOSPHOPEPTIDE-SPECIFIC LC13 TCR, MONOCLINIC CRYSTAL FORM
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 19-BM |
| Synchrotron site | APS |
| Beamline | 19-BM |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2019-03-19 |
| Detector | ADSC QUANTUM 210r |
| Wavelength(s) | 0.9794 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 39.679, 77.228, 67.680 |
| Unit cell angles | 90.00, 104.38, 90.00 |
Refinement procedure
| Resolution | 33.710 - 1.660 |
| R-factor | 0.1689 |
| Rwork | 0.167 |
| R-free | 0.21640 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1oga |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.421 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0073) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 33.710 | 1.690 |
| High resolution limit [Å] | 1.660 | 1.660 |
| Rmerge | 0.052 | 0.650 |
| Number of reflections | 46274 | 2098 |
| <I/σ(I)> | 12.1 | 2.7 |
| Completeness [%] | 98.8 | 89.2 |
| Redundancy | 3.1 | 2.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 290 | 20-28%PEG1000, 0.1M HEPES-NAOH, PH 7.5, VAPOR DIFFUSION, SITTING DROP, TEMPERATURE 290K |