7RG6

Importin alpha2 in complex with ORF4B Bat coronavirus HKU5

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]80
Detector technologyPIXEL
Collection date2021-03-13
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9537
Spacegroup nameP 21 21 21
Unit cell lengths78.692, 90.310, 100.000
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.660 - 2.100
R-factor0.2058
Rwork0.205
R-free0.22280
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6bvt
RMSD bond length0.002
RMSD bond angle0.480
Data reduction softwareiMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.19rc4_4035)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]29.9902.270
High resolution limit [Å]2.1002.200
Rmerge0.0841.160
Rpim0.0590.831
Number of reflections421184172
<I/σ(I)>12.82.3
Completeness [%]99.9
Redundancy5.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2960.1M HEPES pH6.5, 0.6M Citrate, 0.01M DTT

237423