7RG4
Importin alpha2 in complex with p50 NLS
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2017-11-05 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9537 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 78.015, 89.748, 97.204 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.920 - 2.600 |
R-factor | 0.218 |
Rwork | 0.216 |
R-free | 0.24300 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6bvt |
RMSD bond length | 0.002 |
RMSD bond angle | 0.473 |
Data reduction software | iMOSFLM |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.19rc4_4035) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 29.920 | 2.720 |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 0.127 | 1.321 |
Rpim | 0.059 | 0.630 |
Number of reflections | 21620 | 2587 |
<I/σ(I)> | 10.8 | 2.1 |
Completeness [%] | 99.9 | |
Redundancy | 10.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 296 | 0.7 M sodium citrate, 0.01M DTT, 0.1M sodium HEPES pH 7 |