Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7QLY

Endothiapepsin apo at 298K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]298
Detector technologyPIXEL
Collection date2021-09-08
DetectorDECTRIS EIGER2 X 16M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths45.971, 74.173, 53.541
Unit cell angles90.00, 109.78, 90.00
Refinement procedure
Resolution37.370 - 1.790
R-factor0.1907
Rwork0.189
R-free0.21840
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6rsv
RMSD bond length0.002
RMSD bond angle0.605
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]37.3701.850
High resolution limit [Å]1.7901.790
Rmeas0.1602.100
Number of reflections325293095
<I/σ(I)>7.580.97
Completeness [%]98.797.3
Redundancy6.846.52
CC(1/2)0.9900.420
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62930.1 M ammonium acetate, 0.1 M sodium acetate pH 4.6, and 26 - 30% (v/v) PEG 4000

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon