Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7QLU

Endothiapepsin apo at 100K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2021-09-08
DetectorDECTRIS EIGER2 X 16M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths45.683, 72.460, 53.377
Unit cell angles90.00, 110.35, 90.00
Refinement procedure
Resolution35.130 - 1.410
R-factor0.2001
Rwork0.199
R-free0.23150
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6rsv
RMSD bond length0.007
RMSD bond angle0.955
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.1301.460
High resolution limit [Å]1.4101.410
Rmeas0.0801.550
Number of reflections604485856
<I/σ(I)>15.481.34
Completeness [%]96.293.26
Redundancy6.776.63
CC(1/2)0.9900.730
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62930.1 M ammonium acetate, 0.1 M sodium acetate pH 4.6, and 26 - 30% (v/v) PEG 4000

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon