7Q47
Endolysin from bacteriophage Enc34, catalytic domain
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | MAX IV BEAMLINE BioMAX |
| Synchrotron site | MAX IV |
| Beamline | BioMAX |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2020-07-08 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.9763 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 65.304, 128.993, 36.279 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 45.890 - 1.600 |
| R-factor | 0.179 |
| Rwork | 0.177 |
| R-free | 0.20910 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | Enc34 ORF39-SeMet |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.519 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 45.890 | 45.890 | 1.700 |
| High resolution limit [Å] | 1.600 | 5.000 | 1.600 |
| Rmerge | 0.168 | 0.089 | 1.525 |
| Rmeas | 0.175 | 0.093 | 1.597 |
| Total number of observations | 503383 | ||
| Number of reflections | 41411 | 1507 | 6765 |
| <I/σ(I)> | 9.9 | 21.94 | 2.03 |
| Completeness [%] | 100.0 | 99.7 | 100 |
| Redundancy | 12.156 | 11.565 | 11.394 |
| CC(1/2) | 0.996 | 0.995 | 0.768 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 4.2 | 293 | 0.1 M phosphate/citrate, 0.2 M sodium chloride, 20% w/v PEG 8000 |