7PUC
CARM1 in complex with EML981
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 2 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-11-08 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 0.98 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 75.322, 98.943, 208.195 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.130 - 2.190 |
R-factor | 0.2037 |
Rwork | 0.202 |
R-free | 0.23050 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5ih3 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.130 | 2.230 |
High resolution limit [Å] | 2.190 | 2.190 |
Rmerge | 0.158 | 2.821 |
Rmeas | 0.164 | 2.950 |
Rpim | 0.063 | 0.843 |
Number of reflections | 80457 | 3971 |
<I/σ(I)> | 11.1 | 1.1 |
Completeness [%] | 99.2 | 87 |
Redundancy | 13.3 | 11.7 |
CC(1/2) | 0.999 | 0.511 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 293 | 15% PEG 3350, 200mM AMMONIUM SULFATE, 100mM TRIS HCL pH8.5 |