Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7PHY

Vaccinia virus E2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2018-05-22
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97949
Spacegroup nameP 21 21 21
Unit cell lengths77.167, 90.925, 147.205
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution35.520 - 2.300
R-factor0.1943
Rwork0.192
R-free0.23700
Structure solution methodSIRAS
RMSD bond length0.008
RMSD bond angle0.866
Data reduction softwareDIALS
Data scaling softwareDIALS
Phasing softwareCRANK2
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.1702.340
High resolution limit [Å]2.3002.300
Rmerge0.0742.422
Rmeas0.0772.526
Rpim0.0210.708
Number of reflections468472338
<I/σ(I)>190.6
Completeness [%]100.0100
Redundancy13.212.4
CC(1/2)1.0000.404
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293200 nL of 9.7 mg/mL VACV E2 was mixed with 90 nL of reservoir, 100 mM ADA (1:1 mix of ADA pH 6.5 and 7.0), 10% MPD, and equilibrated against an 80 uL reservoir at 20C.

223790

PDB entries from 2024-08-14

PDB statisticsPDBj update infoContact PDBjnumon