7PGF
Calcium-selective Sp1 channel pore domain only
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.3.1 |
Synchrotron site | ALS |
Beamline | 8.3.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-10-01 |
Detector | MAR CCD 130 mm |
Wavelength(s) | 1.11587 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 133.682, 133.682, 130.744 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 14.930 - 3.500 |
R-factor | 0.2658 |
Rwork | 0.265 |
R-free | 0.28970 |
Structure solution method | MAD |
RMSD bond length | 0.010 |
RMSD bond angle | 1.449 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.622 |
High resolution limit [Å] | 3.500 | 3.500 |
Rmerge | 0.156 | 1.000 |
Number of reflections | 9000 | 879 |
<I/σ(I)> | 10.2 | |
Completeness [%] | 97.2 | |
Redundancy | 11.5 | |
CC(1/2) | 0.995 | 0.126 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | CaVSp1p purified in DM was concentrated to 13 mg mL-1 and reconstituted in bicelles prior crystallization to a final bicelle concentration of 8%. Native crystals grew in 25% PEG4000, 200 mM MgCl2, 100 mM MES, pH 6.5 |