7PCV
Crystal structure of RBM5 RRM1-zinc finger
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-08-31 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.872600 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 60.380, 39.880, 96.850 |
Unit cell angles | 90.00, 96.03, 90.00 |
Refinement procedure
Resolution | 33.220 - 2.420 |
R-factor | 0.2613 |
Rwork | 0.258 |
R-free | 0.31310 |
Structure solution method | SAD |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 33.220 | 33.220 | 2.490 |
High resolution limit [Å] | 2.420 | 10.840 | 2.420 |
Rmerge | 0.148 | 0.051 | 1.183 |
Rmeas | 0.179 | 0.062 | 1.458 |
Total number of observations | 26716 | ||
Number of reflections | 8712 | 112 | 535 |
<I/σ(I)> | 5.45 | 14.93 | 0.9 |
Completeness [%] | 97.6 | 95.7 | 81.9 |
Redundancy | 3.067 | 3.027 | 2.733 |
CC(1/2) | 0.989 | 0.999 | 0.247 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 277 | 0.1M BICINE pH 8.5, 12% PEG 6000, 10% 1M cesium chloride |